Nicholls and Cooke

Bay Poles: Calculations


Calculating imposed weights:

Typical weights of materials

Floors
220 kg per sq.m
Roof loading
250kg per sq.m
Rendering or tile hung stud work
100kg per sq.m
Single Wall Brickwork
225kg per sq.m
Double Wall Brickwork
450kg per sq.m

Add extra for upstairs window frames and glass, snow, other imposed weights and wind, all of which vary from site to site. Do not underestimate values.

The next step is to choose the right pole for the load. All poles have different ratings depending on pole material, length, diameter and wall thickness.

All of our Poles are load certificated.

Maximum Loading for Bay Poles - Hydraulic Test Results (Nicholls & Cooke)

Height Of Pole in mm Max. Load 51 x 2mm Aluminium Max. Load 38mm Steel Rehau Duraflex Kommerling Plusplan Max. Load 42mm Steel Eurocell Status 6318 Profile 22 Deceunick Max. Load 48mm Steel Status 70 Deceunick Shield
Kg Kn Kg Kn Kg Kn Kg Kn
1000 1478 14.5 3500 34.34 4500 44.15 5000 49.05
1100 1376 13.5 3000 29.34 4000 39.29 5000 49.05
1200 1252 12.29 3000 29.34 4000 39.29 5000 49.05
1300 1159 11.37 3000 29.34 3500 34.34 5000 49.05
1400 1040 10.21 2500 24.52 3000 29.43 5000 49.05
1500 945 9.28 2000 19.62 3000 29.43 4000 39.29
1600 874 8.58 1500 14.72 2500 24.43 4000 39.29
1700 803 7.88 1000 9.81 2500 24.52 3500 34.34
1800 732 7.19 1000 9.81 2000 19.62 3500 34.34
1900 614 6.06 1000 9.81 2000 19.62 3000 29.43
2000 567 5.57 1000 9.81 1500 14.72 3000 29.43
2100 528 5.18 1000 9.81 1500 14.72 2500 24.43